 www..com
FERROXCUBE
DATA SH EET A SHEET
E32/6/20 Planar E cores and accessories
Supersedes data of February 2002 2004 Sep 01
www..com
Ferroxcube
Planar E cores and accessories
CORES Effective core parameters of a set of E cores SYMBOL (I/A) Ve Ie Ae Amin m PARAMETER core factor (C1) effective volume effective length effective area minimum area mass of core half VALUE 0.323 5380 41.4 130 130 13 UNIT mm-1 mm3 mm mm2 mm2 g
R0.25 typ.
handbook, halfpage
E32/6/20
31.75 0.64 24.9 min. 6.35 0.13 3.18 0.2 6.35 0.13
20.32 0.41
R0.64 ref. typ.
CBW407
Dimensions in mm.
Fig.1 E32/6/20.
Effective core parameters of an E/PLT combination SYMBOL (I/A) Ve Ie Ae Amin m PARAMETER core factor (C1) effective volume effective length effective area minimum area mass of plate VALUE 0.278 4560 35.1 130 130 10 UNIT mm-1 mm3 mm mm2 mm2 g
handbook, halfpage
31.75 0.64 3.18 0.13
Ordering information for plates GRADE 3C90 3C92 3C93 3C94 3C96 3F3 3F4 TYPE NUMBER PLT32/20/3-3C90 PLT32/20/3-3C92 PLT32/20/3-3C93 PLT32/20/3-3C94 PLT32/20/3-3C96 PLT32/20/3-3F3 PLT32/20/3-3F4
Dimensions in mm.
20.32 0.41
R0.64 ref. typ.
CBW408
Fig.2 PLT32/20/3.
2004 Sep 01
2
www..com
Ferroxcube
Planar E cores and accessories
E32/6/20
Core halves for use in combination with an E core AL measured in combination with a non-gapped core half, clamping force for AL measurements, 30 10 N, unless stated otherwise. GRADE 3C90 AL (nH) 160 3%(1) 250 3%(1) 315 3% 400 5% 630 8% 6425 25% 3C92 3C93 3C94 5000 25% 5900 25% 160 3%(1) 250 3%(1) 315 3% 400 5% 630 8% 6425 25% 3C96 3F3 6425 25% 160 3%(1) 250 3%(1) 315 3% 400 5% 630 8% 5900 25% 3F4 160 3%(1) 250 3%(1) 315 3% 400 5% 630 8% 3200 25% Note 1. Measured in combination with an equal gapped E core half, clamping force for AL measurements, 30 10 N. e 41 64 81 103 162 1650 1290 1520 41 64 81 103 162 1650 1650 41 64 81 103 162 1520 41 64 81 103 162 820 AIR GAP (m) 1200 700 550 450 260 0 0 0 1200 700 550 450 260 0 0 1200 700 550 450 260 0 1200 700 550 450 260 0 TYPE NUMBER E32/6/20-3C90-E160-E E32/6/20-3C90-E250-E E32/6/20-3C90-A315-E E32/6/20-3C90-A400-E E32/6/20-3C90-A630-E E32/6/20-3C90 E32/6/20-3C92 E32/6/20-3C93 E32/6/20-3C94-E160-E E32/6/20-3C94-E250-E E32/6/20-3C94-A315-E E32/6/20-3C94-A400-E E32/6/20-3C94-A630-E E32/6/20-3C94 E32/6/20-3C96 E32/6/20-3F3-E160-E E32/6/20-3F3-E250-E E32/6/20-3F3-A315-E E32/6/20-3F3-A400-E E32/6/20-3F3-A630-E E32/6/20-3F3 E32/6/20-3F4-E160-E E32/6/20-3F4-E250-E E32/6/20-3F4-A315-E E32/6/20-3F4-A400-E E32/6/20-3F4-A630-E E32/6/20-3F4
2004 Sep 01
3
www..com
Ferroxcube
Planar E cores and accessories
Core halves for use in combination with a plate (PLT) AL measured in combination with a plate (PLT), clamping force for AL measurements, 30 10 N. GRADE 3C90 AL (nH) 160 3% 250 3% 315 3% 400 5% 630 8% 7350 25% 3C92 3C93 3C94 5760 25% 6780 25% 160 3% 250 3% 315 3% 400 5% 630 8% 7350 25% 3C96 3F3 7350 25% 160 3% 250 3% 315 3% 400 5% 630 8% 6780 25% 3F4 160 3% 250 3% 315 3% 400 5% 630 8% 3700 25% e 35 55 69 87 138 1610 1270 1500 35 55 69 87 138 1610 1610 35 55 69 87 138 1490 35 55 69 87 138 810 AIR GAP (m) 1200 700 550 450 260 0 0 0 1200 700 550 450 260 0 0 1200 700 550 450 260 0 1200 700 550 450 260 0
E32/6/20
TYPE NUMBER E32/6/20-3C90-A160-P E32/6/20-3C90-A250-P E32/6/20-3C90-A315-P E32/6/20-3C90-A400-P E32/6/20-3C90-A630-P E32/6/20-3C90 E32/6/20-3C92 E32/6/20-3C93 E32/6/20-3C94-A160-P E32/6/20-3C94-A250-P E32/6/20-3C94-A315-P E32/6/20-3C94-A400-P E32/6/20-3C94-A630-P E32/6/20-3C94 E32/6/20-3C96 E32/6/20-3F3-A160-P E32/6/20-3F3-A250-P E32/6/20-3F3-A315-P E32/6/20-3F3-A400-P E32/6/20-3F3-A630-P E32/6/20-3F3 E32/6/20-3F4-A160-P E32/6/20-3F4-A250-P E32/6/20-3F4-A315-P E32/6/20-3F4-A400-P E32/6/20-3F4-A630-P E32/6/20-3F4
2004 Sep 01
4
www..com
Ferroxcube
Planar E cores and accessories
Properties of core sets under power conditions B (mT) at GRADE H = 250 A/m; f = 10 kHz; T = 100 C 320 320 370 370 320 320 320 320 320 320 300 300 250 250 f = 100 kHz; B = 100 mT; T = 100 C 0.65 0.55 0.48 0.41 0.48(1) 0.41(1) 0.48 0.41 0.36 0.3 0.65 0.6 - - CORE LOSS (W) at f = 100 kHz; B = 200 mT; T = 100 C - - 3.4 2.9 3.4(1) 2.9(1) 3.4 2.9 2.6 2.2 - - - -
E32/6/20
f = 400 kHz; B = 50 mT; T = 100 C - - - - - - - - 0.9 0.8 1.0 0.85 - -
E+E32-3C90 E+PLT32-3C90 E+E32-3C92 E+PLT32-3C92 E+E32-3C93 E+PLT32-3C93 E+E32-3C94 E+PLT32-3C94 E+E32-3C96 E+PLT32-3C96 E+E32-3F3 E+PLT32-3F3 E+E32-3F4 E+PLT32-3F4
Measured at 140 C.
1.
Properties of core sets under power conditions (continued) B (mT) at GRADE H = 250 A/m; f = 10 kHz; T = 100 C 320 320 370 370 320 320 320 320 320 320 300 300 250 250 f = 500 kHz; B = 50 mT; T = 100 C - - - - - - - - 2.0 1.7 - - - - CORE LOSS (W) at f = 500 kHz; B = 100 mT; T = 100 C - - - - - - - - - - - - - - f = 1 MHz; B = 30 mT; T = 100 C - - - - - - - - - - - - 1.6 1.36 f = 3 MHz; B = 10 mT; T = 100 C - - - - - - - - - - - - 2.5 2.2
E+E32-3C90 E+PLT32-3C90 E+E32-3C92 E+PLT32-3C92 E+E32-3C93 E+PLT32-3C93 E+E32-3C94 E+PLT32-3C94 E+E32-3C96 E+PLT32-3C96 E+E32-3F3 E+PLT32-3F3 E+E32-3F4 E+PLT32-3F4
2004 Sep 01
5
www..com
Ferroxcube
Planar E cores and accessories
DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS Preliminary specification Product specification PRODUCT STATUS Development DEFINITIONS
E32/6/20
This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product.
Production
DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS Prototype Design-in Preferred Support INDICATION DEFINITION These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. These products are recommended for new designs. These products are recommended for use in current designs and are available via our sales channels. These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability.
2004 Sep 01
6


▲Up To Search▲   

 
Price & Availability of E32

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X